Communication Manager Maintenance Object Repair Procedures<br />

Table 627: DSP Port Status Query Test (#1407) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system error.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

FAIL Unable to get status for this port. Verify that this board has been<br />

administered correctly, and that there are no alarms against this board.<br />

PASS The board is functioning properly and the port is in-service and<br />

available.<br />

0 NO<br />

BOARD<br />

See NO BOARD for repair procedures.<br />

Firmware Download Test (#1413)<br />

This test is destructive.<br />

This test has two functions and can only be executed if there is a download schedule to verify or<br />

if there are FW-DWNLD errors to resolve and alarms to clear.<br />

1. This test verifies that the information on the FIRMWARE DOWNLOAD screen is correct. It<br />

also verifies that the source board is of the correct type, the file to be downloaded is present<br />

on that source board, and the file is free of errors. In addition, it verifies that the target board<br />

code and suffix are correct. It also retrieves the new firmware vintage for the target board<br />

and populates the appropriate field in the firmware download table.<br />

2. If this test is executed after a FIRMWARE DOWNLOAD schedule has run and there are<br />

FW-DWNLD alarms/errors, it resolves the errors, clears the alarms, copies the current<br />

download status table to the last table, and clears out the current table.<br />

Table 628: Firmware Download Test (#1413) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

2014 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />