Table 386: Digital Station Audits Test (#17) 4 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Looparound and Conference Test (#33)<br />

Looparound and Conference Test (#33)<br />

1706 ABORT IP endpoint is not registered.<br />

1. Verify the IP phone is connected.<br />

2. Retry the command at 1-minute intervals up to 5 times.<br />

2000 ABORT Response to the test was not received within the time allowed.<br />

2100 Internal error.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

FAIL Internal system error<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

PASS The audits passed.<br />

1. If complaints still exist, investigate by using other port tests and by<br />

examining the data module options, wiring, and connections.<br />

The Looparound and Conference Test checks the reflective and non-reflective looparound and<br />

conference capabilities of a trunk port circuit. It transmits 404-Hz, 1004-Hz, and 2804-Hz tones.<br />

Each tone is transmitted separately to and from the port, then verified<br />

Disabling this test also disables the Port Diagnostic Test (#35).<br />

This test runs on the following maintenance objects:<br />

● AUX-TRK (Auxiliary Trunk)<br />

● CO-TRK (Analog CO Trunk)<br />

● DID-TRK (Direct Inward Dial Trunk)<br />

● DIOD-TRK (DIOD Trunk)<br />

● TIE-TRK (Analog Tie Trunk)<br />

Description / Recommendation<br />

4 of 4<br />

Communication Manager Release 5.0 Issue 4 January 2008 1479