Communication Manager Maintenance Object Repair Procedures<br />

Expansion Interface Lightwave Transceiver<br />

Looparound Test (#242)<br />

This test is destructive.<br />

This test requires that the EI circuit pack first be busied out. If the system has a duplicated Port<br />

Network Connectivity, this test cannot be run on an EI circuit pack that resides on the current<br />

active PNC due to restrictions that prohibit the busying-out of certain components that are part<br />

of the active PNC. If this test is run on an EI circuit pack that is part of the standby PNC, this test<br />

is not destructive and no service outages will take place.<br />

In a system without duplicated Port Network Connectivity, where this EI circuit supports an IPSI<br />

to PN link, this test will disrupt service to one or more PN’s. If the EI circuit pack is part of a<br />

PN-to-PN link in a Direct Connect system, service between the two PNs will be disrupted.<br />

This is a 2-part connectivity test. In the first part of the test, a digital count is transmitted from the<br />

cabinet of the EI circuit pack under test, through the EI circuit pack under test, out to its<br />

lightwave transceiver. The connection then loops back into the lightwave transceiver, through<br />

the same EI circuit pack again, and into the originating cabinet. If the test tone is detected by a<br />

tone detector, the first part of the test passes. The path used for this part of the test is<br />

represented in Figure 134: TDM BUS Lightwave Transceiver Looparound.<br />

In the second part of the test, a data packet is sent from the TN1655 Packet Interface circuit<br />

pack to the EI circuit pack under test, the packet is looped back through the lightwave<br />

transceiver and is sent back to the Packet Interface circuit pack. If the Packet Interface circuit<br />

pack receives the same packet it transmitted, the second part of the test passes. If the entire<br />

test has passed, the EI circuit pack, its backplane wiring, and the electrical portion of the<br />

lightwave transceiver are healthy. The path used for this test is represented in<br />

Figure 135: Packet Bus Lightwave Transceiver Looparound—PN only. The path used for this<br />

test if the EI resides in a PN is represented in Figure 136: Packet Bus Lightwave Transceiver<br />

Looparound—CSS and PN.<br />

When the EI circuit pack under test is in a PN, the data packet must also pass through the active<br />

EI circuit packs and the active DS1 converter circuit packs (and the active SNI circuit pack(s) in<br />

a Center Stage Switch system) of the active PNC link connecting the PN.<br />

This test requires the EI circuit pack to ignore incoming data from its neighbor EI circuit pack or<br />

SNI circuit pack. Thus this test will:<br />

● Disturb any inter-PN connections that currently exist over the link provided by the EI under<br />

test and its neighbor<br />

● Disrupt signaling between the two circuit packs<br />