09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Communication Manager Maintenance Object Repair Procedures<br />

Table 454: Data Module Internal Looparound Test (#175) 3 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2000 ABORT Data module is disconnected.<br />

1. Verify that the data module is powered (power LED on).<br />

2. Make sure data module is connected to the building wiring. Check for<br />

faulty wiring and faulty data module.<br />

3. Retry the command at one-minute intervals a maximum of 5 times.<br />

4. Replace the Data Module and repeat the test.<br />

5. If the test continues to abort, replace the Digital Line circuit pack and<br />

repeat the test.<br />

2005 ABORT The handshake between the Maintenance/Test digital port and the Data<br />

Module failed.<br />

1. Look for M/T-DIG errors in the Error Log. If present, see M/T-DIG<br />

(Maintenance/Test Digital Port).<br />

2. If test still aborts on retry, check physical connection of data module<br />

under test. Make sure the switches are on NORM, OFF (between<br />

REM_LP and LOC_LP), 9600, and ASYN.<br />

3. If the test still aborts, replace the Data Module.<br />

2012 ABORT System call failed. Internal error.<br />

1. Try the command again at 1-minute intervals up to 5 times.<br />

2312 ABORT The looparound test failed to receive loopback data.<br />

1. Check for M/T-DIG error in the Error Log. If present, see M/T-DIG<br />

(Maintenance/Test Digital Port).<br />

2. Retry the test. If it still aborts, replace the Data Module and retest.<br />

3. If the test aborts again, replace the Digital Line circuit pack.<br />

2313 ABORT The Maintenance/Test digital port allocated for this test did not respond to<br />

downlinked message.<br />

1. Look for M/T-DIG errors in the Error Log. If present, see M/T-DIG<br />

(Maintenance/Test Digital Port).<br />

2. Retry the command at 1-minute intervals up to 5 times.<br />

3. If the test continues to abort, replace the MTB.<br />

1638 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

3 of 4