Figure 145: Loopback Points for Test #799<br />

Table 551: Near-End External Loopback Test (#799) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

DS1CONV<br />

A<br />

Test starts here<br />

LB 1<br />

CSU A<br />

LB 2<br />

DS1 Facility<br />

Description / Recommendation<br />

Near-End External Loopback Test (#799)<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

2000 Test timed out while waiting for a response from the circuit pack.<br />

2300 The downlink message necessary to run this test could not be sent.<br />

2301 The timer could not be set before sending the downlink message.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2316 ABORT Fiber link is not administered.<br />

1. Enter add fiber-link to administer the DS1 converter fiber link.<br />

2321 ABORT DS1 facility is not busied out.<br />

1. Busyout the DS1 facility via busyout ds1-facility.<br />

2. If there is only one DS1 facility, busyout the DS1 converter circuit<br />

pack via busyout board.<br />

2332 ABORT With this system configuration, the test cannot run at the far end when<br />

there is only one DS1 facility available. Check the green LED at the face<br />

plate of the DS1 converter circuit pack. The green LED should be on if the<br />

loop is complete.<br />

CSU B<br />

DS1CONV<br />

B<br />

2500 ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

1 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 1867