Assessment of Indoor Air Quality in Two Different Laboratories at<br />

Kompleks Makmal Berpusat, Universiti Malaysia Terengganu<br />

Nurul Shafiqa Binti Mokhtar Rudin<br />

Supervisor: Dr. Nurul Adyani Binti Ghazali<br />

Bachelor of Technology (Environment)<br />

School of Ocean Engineering<br />

Universiti Malaysia Terengganu<br />

Indoor air pollution in university laboratories are important to the occupants, especially<br />

for those who work in the laboratories. The aim of this study is to determine the<br />

compliance of air pollutant which is Particulate Matter (PM₁₀) and two meteorological<br />

factors which are temperature and relative humidity in two university laboratories with<br />

the guideline limit recommended by Industry Code of Practice 2010 (ICOP 2010). The<br />

sampling carried out from 0830 to 1630 for 3 days during weekdays and the<br />

measurements are taken by using indoor air quality instruments. Results show the<br />

concentration for PM₁₀ and relative humidity are exceeded the limit from ICOP 2010<br />

with 669µg/m³ and 70.4% respectively while temperature remained in range with<br />

24.9°C. Results from ANOVA show that there are significant differences recorded for<br />

all the parameters. As conclusion, there are two parameters that exceeded the limit<br />

therefore, it is necessary measure needed to improve the thermal comfort.<br />