05.02.2013 Views

ARM Architecture Reference Manual ARMv7-A and ARMv7-R edition

ARM Architecture Reference Manual ARMv7-A and ARMv7-R edition

ARM Architecture Reference Manual ARMv7-A and ARMv7-R edition

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Register In a Description, see<br />

Register Index<br />

DTCMRR, <strong>ARM</strong>v6 c9, TCM Region Registers (DTCMRR <strong>and</strong> ITCMRR) on page AppxG-47<br />

DTLBIALL VMSA CP15 c8, TLB maintenance operations on page B3-138<br />

DTLBIASID VMSA CP15 c8, TLB maintenance operations on page B3-138<br />

DTLBIMVA VMSA CP15 c8, TLB maintenance operations on page B3-138<br />

DTLBLR, pre-<strong>ARM</strong>v7 c10, VMSA TLB lockdown support on page AppxH-59<br />

ENDIANSTATE ENDIANSTATE on page A2-19<br />

Event The Event Register on page B1-46<br />

Event Catch Event Catch Register (DBGECR) on page C10-78<br />

Event Count c9, Event Count Register (PMXEVCNTR) on page C10-116<br />

Event Counter Selection c9, Event Counter Selection Register (PMSELR) on page C10-113<br />

Event Select c9, Event Type Select Register (PMXEVTYPER) on page C10-115<br />

Extended Access Permissions,<br />

pre-<strong>ARM</strong>v6<br />

FAR See Fault Address<br />

Table K-1 Register index (continued)<br />

c5, Memory Region Extended Access Permissions Registers (DEAPR<br />

<strong>and</strong> IEAPR) on page AppxH-46<br />

Fault Address c6, Data Fault Address Register (DFAR) on page B4-57 (PMSA)<br />

c6, Data Fault Address Register (DFAR) on page B3-124 (VMSA)<br />

c6, Instruction Fault Address Register (IFAR) on page B4-58 (PMSA)<br />

c6, Instruction Fault Address Register (IFAR) on page B3-125 (VMSA)<br />

Watchpoint Fault Address Register (DBGWFAR) on page C10-28<br />

c6, Watchpoint Fault Address Register (DBGWFAR) on page AppxG-37<br />

(<strong>ARM</strong>v6)<br />

Fault Status PMSA c5, Data Fault Status Register (DFSR) on page B4-55<br />

c5, Instruction Fault Status Register (IFSR) on page B4-56<br />

VMSA c5, Data Fault Status Register (DFSR) on page B3-121<br />

c5, Instruction Fault Status Register (IFSR) on page B3-122<br />

FCSE Process ID VMSA c13, FCSE Process ID Register (FCSEIDR) on page B3-152<br />

FCSEIDR VMSA c13, FCSE Process ID Register (FCSEIDR) on page B3-152<br />

Floating-point Exception The Floating-Point Exception Register (FPEXC) on page B1-68<br />

<strong>ARM</strong> DDI 0406B Copyright © 1996-1998, 2000, 2004-2008 <strong>ARM</strong> Limited. All rights reserved. AppxK-11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!