Communication Manager Maintenance Object Repair Procedures<br />

Aux data <strong>error</strong> <strong>codes</strong> <strong>and</strong> recommended repair procedures<br />

Table 24: Aux data <strong>error</strong> <strong>codes</strong> <strong>and</strong> recommended repair procedures 1 of 2<br />

Aux data Description/ Recommendation<br />

32001 Internal system <strong>error</strong>.<br />

1. Check other ANNOUNCE <strong>error</strong>s <strong>and</strong> take corrective action.<br />

2. If there are no ANNOUNCE <strong>error</strong>s, retry the comm<strong>and</strong> at 2-minute intervals<br />

a maximum of 3 times.<br />

3. If restore announcements fails, escalate the problem.<br />

32002 Announcement circuit pack is in use.<br />

1. Retry the comm<strong>and</strong> at 2-minute intervals a maximum of three times.<br />

2. If restore announcements fails, escalate the problem.<br />

32003 Announcement port is in use.<br />

1. Wait for all announcement ports to become available.<br />

2. Enter save/restore announcements.<br />

32004 There are no announcements recorded on the announcement Circuit Pack. Save<br />

announcements does not prevent the destroying of the announcement file on<br />

tape [286 systems] or on the memory card [386 systems].<br />

32005 Integrated announcement circuit pack is not present. The Announcement Circuit<br />

Pack is not inserted, or it is defective.<br />

1. Enter list config to check for the presence of the circuit pack in the<br />

system.<br />

2. If the announcement Circuit Pack is present, use <strong>test</strong> board location<br />

to check the status of the announcement Circuit Pack.<br />

32006 Announcement Data Module not available.<br />

1. Enter status to check the status of the Announcement Data Module.<br />

32007 Announcement Data Module out of service.<br />

1. Enter status to check the status of the Announcement Data Module.<br />

32008 Announcement data is being saved or loaded.<br />

1. Retry the comm<strong>and</strong> at 2-minute intervals a maximum of three times.<br />

2. If save/restore announcements fails, escalate the problem.<br />