Table 79: DAT-LINE Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

15(b) Any Port Audit <strong>and</strong><br />

Update (#36)<br />

18 0 busyout port<br />

location<br />

WRN OFF rel port location<br />

130 (c) WRN ON <strong>test</strong> port location<br />

257 Conference<br />

Circuit Test (#7)<br />

513 NPE Crosstalk<br />

Test (#6)<br />

769(d) 40983<br />

On/Off<br />

Board<br />

Recommended Action<br />

MIN ON <strong>test</strong> port location l r 2<br />

MIN ON <strong>test</strong> port location l r 2<br />

Notes:<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description, <strong>and</strong> follow its recommended procedures.<br />

b. Error Type 15: Software audit <strong>error</strong> that does not indicate any hardware malfunction. Run<br />

the short <strong>test</strong> sequence, <strong>and</strong> investigate <strong>error</strong>s.<br />

c. Error Type 130: The circuit pack has been removed or has been insane for more than<br />

11-minutes. To clear the <strong>error</strong>, reseat or replace the circuit pack.<br />

d. Error Type 769: the data line circuit pack found an <strong>error</strong> in the transmit/receive circuitry of<br />

an administered data line when the circuit pack was inserted. Perform the following:<br />

1. Enter busyout board location for the circuit pack on which the port resides.<br />

2. Enter reset board location. Check the Error Log to determine whether Error<br />

Type #769 is logged again for DAT-LINE. Verify that the Active Alarms Only field is n.<br />

If Error Type #769 reappears, replace the data line circuit pack. If not, enter<br />

release board location.<br />

298 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />