IPMEDPRO (TN2302 IP Media Processor)<br />

If the circuit pack type is TN2602AP, see IPMEDPRO (TN2602AP IP Media Resource 320).<br />

MO Name in Log Alarm<br />

Level<br />

IPMEDPRO MAJ<br />

MIN<br />

The TN2302 (IP Media Processor) circuit pack is the next generation VOIP platform. The<br />

TN2302 includes a 10/100 BaseT Ethernet interface to support IP audio for IP trunks <strong>and</strong> H.323<br />

endpoints. The TN2302 can perform echo cancellation, silence suppression, DTMF detection,<br />

<strong>and</strong> conferencing. It supports the following codecs, fax detection for them, <strong>and</strong> conversion<br />

between them:<br />

● G.711 (mu-law or a-law, 64 kbps)<br />

● G.723.1 (6.3-kbps or 5.3-kbps audio)<br />

Initial Comm<strong>and</strong> to Run Full Name of MO<br />

<strong>test</strong> board location l IP Media Processor<br />

WRN <strong>test</strong> board location<br />

● G.729A (8-kbps audio)<br />

The TN2302 circuit board provides voice over IP connectivity. The TN2302 acts as a service<br />

circuit to terminate generic RTP streams which carry packetized audio over an IP network. As<br />

part of the overall H.323 implementation, the TN2302 circuit pack h<strong>and</strong>les the audio streams<br />

while the TN799DP C-LAN h<strong>and</strong>les the TCP/IP signaling chels.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 140: TN2302 IPMEDPRO Error Log Entries 1 of 3<br />

Error Type Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 1 0 Any Any Any <strong>test</strong> board location<br />

1 (a) 0 Circuit pack<br />

removed or SAKI<br />

<strong>test</strong> (#53) failed<br />

18 (b) 0 busyout board<br />

location<br />

23 (c) 0 Board<br />

administered but<br />

not inserted<br />

MIN ON<br />

WRN OFF release board location<br />

WRN OFF insert the board into the<br />

system<br />