SNC On-Board Test (#778)<br />

This <strong>test</strong> runs on the SNC-BD (Switch Node Clock Circuit Pack) maintenance object.<br />

Table 446: SNC On-Board Test (#778) 1 of 2<br />

Error<br />

Code<br />

2100<br />

2300<br />

2301<br />

2303<br />

2304<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

The downlink message necessary to run this <strong>test</strong> could not be sent.<br />

The timer could not be set before sending the downlink message.<br />

Test request is not valid.<br />

SNC firmware is not able to run the <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2306 ABORT The SNC circuit pack is not responding to <strong>test</strong> requests sent by<br />

software.<br />

1. Run <strong>test</strong> led switch-node for the switch node where this<br />

board resides to verify whether the LEDs on the board light.<br />

2. If the LEDs on the other boards in the carrier light, but the LEDs<br />

on this board do not light, run Test #760 using <strong>test</strong> board<br />

location l for the active SNC in this carrier. Wait 5 minutes<br />

<strong>and</strong> then try step 1 one more time. If the LEDs on this board still<br />

do not light, replace this board. Replacing an SNC may be<br />

service interrupting. See SNI-BD (SNI Circuit Pack) for the<br />

procedure for replacing an SNC.<br />

3. If none of the LEDs light for the boards in the same carrier as this<br />

board, fix any problems associated with the connectivity of this<br />

carrier to the server.<br />

a. Enter list fiber-link to obtain a list of the fiber<br />

connections to this carrier.<br />

b. Check the LEDs on every SNI <strong>and</strong> EI, <strong>and</strong> fix any fiber<br />

problems.<br />

c. Enter display <strong>error</strong>s, <strong>and</strong> follow the repair procedures<br />

for any EXP-INTF (Expansion Interface Circuit Pack) <strong>error</strong><br />

entries associated with the controlling IPSI connected PN.<br />

d. Follow the repair procedures for any SYNC (Port Network<br />

Synchronization), SNI-BD (SNI Circuit Pack), SNC-BD<br />

(Switch Node Clock Circuit Pack) SNI-PEER (SNI Peer Link)<br />

or FIBER-LK (Fiber Link) <strong>error</strong> entries.<br />

1 of 2<br />

Issue 5 May 2009 1493