19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Table 471: SNI Fiber Out of Frame Query Test (#989) 3 of 8<br />

Error<br />

Code<br />

141<br />

142<br />

Test<br />

Result<br />

Description / Recommendation<br />

SNI Fiber Out of Frame Query Test (#989)<br />

FAIL The SNI circuit pack has a fiber out of frame condition, but no loss of<br />

signal condition.<br />

Error Code 141: A lightwave transceiver is connected to the SNI circuit<br />

pack.<br />

Error Code 142: No lightwave transceiver is connected to the SNI circuit<br />

pack.<br />

1. Check that the connected circuit pack is physically installed. The<br />

connected circuit pack is the other endpoint of the fiber-link if no<br />

DS1C complex is administered. Check using list fiber-link.<br />

Otherwise, if a DS1C complex is administered, the connected circuit<br />

pack is the DS1C circuit pack connected to the SNI circuit pack.<br />

2. If a lightwave transceiver should not be present, go to step 3. For<br />

example, an SNI connected to a DS1C circuit pack or an SNI with a<br />

metallic connection does not have a lightwave transceiver.<br />

Otherwise, check the lightwave transceiver connections. If OK,<br />

replace the lightwave transceiver. If a fiber out-of-frame condition<br />

exists <strong>and</strong> lightwave transceivers are used, check that the lightwave<br />

transceivers are of the same type, that is, both are 9823a or both are<br />

9823b. If they are not the same type, replace one of the lightwave<br />

transceivers:<br />

● 9823a is used for distances up to 4,900 feet.<br />

● 9823b is used for distances up to 25,000 feet.<br />

3. Perform the Fiber link fault isolation procedure in Maintenance<br />

Procedures for <strong>Avaya</strong> Aura Communication Manager, Media<br />

Gateways <strong>and</strong> Servers (03-300432).<br />

4. Replace this SNI circuit pack.<br />

5. Replace the connected circuit pack.<br />

3 of 8<br />

Issue 5 May 2009 1551