Local Loop Test (#13)<br />

This <strong>test</strong> is executed on the following maintenance objects:<br />

● ADX8D-PT (AUDIX Digital Port)<br />

● ADX16D-P (16-Port AUDIX Digital Port)<br />

● DIG-LINE (Digital Line)<br />

● E-DIG-ST (Emulated Digital Line)<br />

● M/T-ANL (Maintenance/Test Analog Port).<br />

● M/T-DIG (Maintenance/Test Digital Port)<br />

● PDMODULE (Processor Data Module)<br />

Local Loop Test (#13)<br />

● TDMODULE (Trunk Data Module).<br />

For ADX8D-PT, ADX16D-P, DIG-LINE, <strong>and</strong> E-DIG-ST, this <strong>test</strong> is known as the Voice <strong>and</strong><br />

Control Chel Local Loop Test (#13). This <strong>test</strong> consists of four <strong>test</strong>s that check the information<br />

<strong>and</strong> control chels between the server <strong>and</strong> the port circuit. If any of the <strong>test</strong>s fail or abort, the <strong>test</strong><br />

sequence stops <strong>and</strong> the result is reported.<br />

For M/T-ANL, this <strong>test</strong> is known as the Analog Port Digital Looparound Test (#13). The <strong>test</strong><br />

performs a loop <strong>test</strong> on the data chel <strong>and</strong> TDM bus, then runs a conference <strong>test</strong>.<br />

For M/T-DIG, this <strong>test</strong> is known as the Digital Port Looparound Test (#13). The <strong>test</strong> performs a<br />

loop <strong>test</strong> on the data chel <strong>and</strong> TDM bus, then runs a conference <strong>test</strong>.<br />

For PDMODULE <strong>and</strong> TDMODULE, this <strong>test</strong> is known as the Information <strong>and</strong> Control Chel<br />

Looparound Test (#13). This is a set of four <strong>test</strong>s that check the operation of the information <strong>and</strong><br />

control chels used between Communication Manager <strong>and</strong> the Digital Line port circuit.<br />

User impact from problems with this port many range from no noticeable effect to not being able<br />

to use this port. Users may not notice a disruption in service. In extreme cases, the<br />

conferencing feature may not work at all.<br />

Table 289: Local Loop Test (#13) 1 of 9<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to abort, escalate the problem.<br />

1 of 9<br />

Issue 5 May 2009 1107