Neon Test (#220)<br />

Neon Test (#220)<br />

This <strong>test</strong> checks the voltage required to light the neon lamp on an analog terminal. A relay<br />

connects a 150V DC source from the backplane of the circuit pack onto the voltage bus, <strong>and</strong><br />

another relay connects a 2K shunt from the bus to ground. Current in the line is then monitored<br />

to determine if the voltage is present.<br />

This <strong>test</strong> runs on XXX-BD (Common Port Circuit Pack/Media Module).<br />

Table 369: Neon Test (#220) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Cot get the list of translated ports on the circuit pack.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1004 ABORT The port was seized by a valid call during the <strong>test</strong>.<br />

1. Enter display port location to determine the station<br />

extension.<br />

2. Enter status station to determine the service state of the port.<br />

If the service state indicates that the port is in use, wait until the<br />

port is idle before re<strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1008 ABORT Could not allocate a ringing circuit. Either all the ringing circuits are in<br />

use, or the ringing generator is defective or is not wired correctly.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to abort, look for RING-GEN <strong>error</strong>s in the Error<br />

Log. If an ABORT 1008 occurs for this <strong>test</strong> on other circuit packs as<br />

well, then the ringing generator may be defective or is not wired<br />

correctly (see <strong>error</strong>s for RING-GEN (Analog Ring Generator)). If<br />

ABORT 1008 does not occur on Test #48 for ANL-16-L, then all<br />

four ring phases are in use.<br />