Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 291: Digital Station Audits Test (#17) 3 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

5 ABORT Ringer update aborted. Data module or station not in the in-service state.<br />

PDMODULE, TDMODULE:<br />

1. Verify that the data module is powered (power LED on).<br />

2. Make sure data module is connected to the building wiring, check<br />

for faulty wiring, check for faulty data module.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

4. Replace the Data Module <strong>and</strong> repeat the <strong>test</strong>.<br />

5. If the <strong>test</strong> continues to abort, replace the Digital Line circuit pack<br />

<strong>and</strong> repeat the <strong>test</strong>.<br />

DIG-LINE, RDIG-STA: The port could have been busied out by a system<br />

technician.<br />

1. Look in the Error Log for Error Type 18 for this port. If this <strong>error</strong> is<br />

present, release the port using release station extension.<br />

2. Make sure that the terminal is connected.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

6 ABORT Touch-tone update failed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

7 ABORT Downloadable parameter downlink failed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

8 ABORT Terminal levels audit failed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1392 ABORT This port is a TTI port. The <strong>test</strong> does not run on TTI ports.<br />

1. Verify that the port is a TTI port using display port, where the<br />

display shows that the port is a TTI port, or list config, where<br />

the display shows a t for the port.<br />

2. If list config or display port indicate that the port is not a<br />

TTI port, escalate the problem. If both comm<strong>and</strong>s indicate that the<br />

port is a TTI port, the abort is correct, <strong>and</strong> no action is necessary.<br />

1120 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />