Table 286: Conference Circuit Test (#7) 6 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Conference Circuit Test (#7)<br />

Any FAIL The NPE of the <strong>test</strong>ed port did not conference the tones correctly. This<br />

causes noisy <strong>and</strong> unreliable connections.<br />

ADX16A-P, DIOD-DS1, ISDN-TRK, PE-BCHL, S-SYN-PT, VC-SUMPT,<br />

WAE-PORT:<br />

1. Replace the circuit pack.<br />

ANL-16-L, AN-LN-PT, DAT-LINE:<br />

1. Enter display port location <strong>and</strong> status station<br />

extension to determine whether the station is idle.<br />

2. If the station is idle, enter <strong>test</strong> port location for this port.<br />

3. If the <strong>test</strong> continues to fail, enter busy port location <strong>and</strong><br />

release port location, <strong>and</strong> then re<strong>test</strong>.<br />

4. If the <strong>test</strong> still fails, replace the circuit pack.<br />

CO-DS1, DID-DS1, OPS-LINE, TIE-DS1:<br />

1. Enter list configuration board location. The circuit pack<br />

must be a TN767C V3 or later. Check the <strong>error</strong> log for Error Type<br />

1281 entries.<br />

2. Test every administered trunk on the board. If one fails, this could be<br />

an off-board problem (such as an incoming seizure or an off-hook<br />

port seizure during the <strong>test</strong>). Re<strong>test</strong> the board.<br />

3. If every port fails, a -5 Volt power problem is indicated. Check<br />

CARR-POW (Carrier Power Supply) or RMC-ENV (Power/Fan<br />

Sensors) for troubleshooting procedures. If a red LED is lit on a<br />

TN736 or TN752 power unit circuit pack, replace the circuit pack.<br />

4. If several ports fail, check the <strong>error</strong> log for TONE-BD (Tone-Clock<br />

Circuit Pack) or TONE-PT (Tone Generator) <strong>error</strong>s. If there are such<br />

<strong>error</strong>s, take the appropriate action. When the TONE <strong>error</strong>s have<br />

cleared, rerun the <strong>test</strong>.<br />

5. If the retry passes <strong>and</strong> troubles are reported, coordinate isolation<br />

with the CO. Verify that the switch, the CO, <strong>and</strong> any NICE<br />

equipment (the CSI’s) have the correct administration.<br />

6. If the <strong>test</strong> still fails, replace the circuit pack.<br />

6 of 7<br />

Issue 5 May 2009 1097