19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Only 2-wire Italtel Digital Telephone Models 1 <strong>and</strong> 2 (IDT1/2) or DAs can directly connect to a<br />

TN2136 circuit pack. <strong>Avaya</strong> DCP (4-wire) digital voice terminals <strong>and</strong> data modules can connect<br />

to these circuit packs via Italtel’s 2/4-wire adapter. DAs operate in either of 2 modes, <strong>and</strong> are<br />

covered by different MOs:<br />

Service States<br />

DA Mode Administered as: Endpoint MO<br />

St<strong>and</strong>alone PDM Data endpoint only PDMODULE<br />

Linked DTDM IDT1/2 <strong>and</strong> optional data terminal DIG-LINE<br />

Digital line maintenance interacts with digital line circuit pack (DIG-BD), or with digital line media<br />

module (MG-DCP) maintenance. The health of the digital-line circuit pack or media module can<br />

affect the results of DIG-LINE <strong>test</strong>ing. Keep this in mind when investigating digital-line<br />

problems.<br />

It is sometimes important to know the service state of a station. These service states apply to<br />

digital-line stations:<br />

Out-of-Service state The port, <strong>and</strong> thus the station, have been removed from service.<br />

The busyout comm<strong>and</strong> puts the port in the out-of-service state.<br />

Ready-for-Service state The port on the circuit pack or media module has been put into<br />

service, but the voice terminal has not yet established signaling<br />

communications with the port.<br />

In-Service state The voice terminal has established signaling communications with<br />

the port, <strong>and</strong> the system is ready to process calls to <strong>and</strong> from that<br />

station. A terminal in the ready-for-service state will progress to the<br />

in-service state if it is functioning normally. It can also be forced<br />

into the in-service state by going off-hook.<br />

Downloading Terminal Parameters<br />

This section explains how maintenance software interacts with terminal parameter<br />

downloading.<br />

320 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers