● POWER<br />

● POW-SUP (Power Supply)<br />

● RING-GEN (Analog Ring Generator)<br />

● RMC-ENV (Power/Fan Sensors)<br />

● SER-BUS (Serial Communication Bus)<br />

Table 327: Ring Generator Initialization Test (#117)<br />

Error<br />

Code<br />

1<br />

1000<br />

1001<br />

1003<br />

1115<br />

2012<br />

2100<br />

Test<br />

Result<br />

Description / Recommendation<br />

Ring Generator Query Test (#118)<br />

Ring Generator Query Test (#118)<br />

ABORT The system is unable to determine the active Tone-Clock circuit pack,<br />

unable to allocated the resources necessary to run the <strong>test</strong>, or unable<br />

to send a downlink message.<br />

1. Wait for the green LED on the active Tone-Clock to go out.<br />

2. Enter status port-network to determine the active<br />

Tone-Clock circuit pack.<br />

3. Rerun the <strong>test</strong>. If the <strong>test</strong> aborts again, see TDM-CLK (TDM Bus<br />

Clock).<br />

2000 ABORT Response from the <strong>test</strong> was not received within the time allowed.<br />

1. Look for TDM-CLK <strong>error</strong>s <strong>and</strong> alarms. Resolve every TDM-CLK<br />

(TDM Bus Clock) problem first.<br />

2. Rerun the <strong>test</strong>.<br />

PASS The active Tone-Clock has successfully been enabled to monitor the<br />

ringing voltage level.<br />

The Ring Generator Query <strong>test</strong> requests the active Tone-Clock circuit pack to check the ringing<br />

voltage. The Tone-Clock circuit pack replies with PASS if the ringing voltage is adequate to ring<br />

the analog phones. If not, the active Tone-Clock circuit pack replies with a FAIL.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● AC-POWER<br />

● CABINET (Cabinet Sensors)<br />

Issue 5 May 2009 1209