Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 379: Signaling Link State Audit Test (#255) 1 of 2<br />

Error<br />

Code<br />

None<br />

or 0<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> up to 5 times at 1-minute intervals.<br />

1018 ABORT Test is disabled by administration.<br />

1. To enable the <strong>test</strong>, enter y in the Maintenance Tests field on the<br />

change trunk-group screen.<br />

1114 ABORT The signaling link is in a transitional state<br />

1. Retry the comm<strong>and</strong> up to 5 times at 1-minute intervals.<br />

1700 ABORT Rollabout video abort for PE-BCHL. The PRI terminal adapter<br />

associated with this PRI endpoint extension is detached from the circuit<br />

pack. This is a normal abort when the rollabout video feature is enabled.<br />

1. Either reconnect the disconnected PRI terminal adapter or disable<br />

the rollabout video feature on this circuit pack. To do the latter,<br />

enter change ds1 location <strong>and</strong> set the Alarm when PRI<br />

Endpoint Detached? field to y.<br />

4 FAIL There is a problem with the signaling chel.<br />

ATM-BCH:<br />

1. Look for <strong>error</strong>s or alarms against ATM-SGRP <strong>and</strong> ATM-DCH, <strong>and</strong><br />

refer to ATM-SGRP (ATM Signaling Group) <strong>and</strong> ATM-DCH (ATM<br />

D-Chel Port) for the appropriate repair procedures.<br />

ISDN-TRK:<br />

1. If the Packet Control circuit pack is used, consult the procedures<br />

for ISDN-SGR (ISDN-PRI Signaling Group). Further information<br />

may also be obtained by consulting the procedures for the<br />

ISDN-PLK (ISDN-PRI Signaling Link Port).<br />

2. If the Packet Interface is used, consult the procedures for PKT-INT<br />

(Packet Interface)<br />

PE-BCH: There is a problem with the Signaling Chel <strong>and</strong>/or with the<br />

System Link.<br />

1. Consult procedures for ISDN-SGR (ISDN-PRI Signaling Group)<br />

<strong>and</strong> SYS-LINK (System Links). See also ISDN-PLK (ISDN-PRI<br />

Signaling Link Port) for useful information.<br />