Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 438: FIBER-LK Configuration Audit (#759) 5 of 10<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

137 FAIL The Endpoint 1 SNI’s administered neighbor does not match the physical<br />

neighbor connected.<br />

1. Enter list fiber-link to see a fiber link’s endpoints. The SNI’s<br />

assigned neighbor is an EI, but the SNI is physically connected to<br />

another SNI.<br />

2. Enter list fiber-link <strong>and</strong> verify that the fiber-optic <strong>and</strong> metallic<br />

cables are installed as administered.<br />

138 FAIL The physical location of SNI Endpoint 1’s neighbor does not match its<br />

administered location.<br />

1. Enter list fiber-link to see a fiber link’s endpoints. One<br />

location (carrier <strong>and</strong> slot) is assigned for the endpoint’s neighbor, but<br />

it physically resides in another location.<br />

2. Enter list fiber-link <strong>and</strong> verify that the fiber-optic <strong>and</strong> metallic<br />

cables are installed as administered.<br />

3. If the problem does not seem to be caused by either a physical<br />

connection or an administration problem, replace the neighbor circuit<br />

pack. The neighbor circuit pack may have a hardware problem<br />

causing it to report a wrong Angel address (physical carrier/slot<br />

address) to software.<br />

139 FAIL The Endpoint 1 SNI is administered to be connected to a DS1 converter,<br />

but is not physically connected to one.<br />

1. Enter list fiber-link to see a fiber link’s endpoints.<br />

If a DS1 converter should be connected to this SNI, enter list<br />

fiber-link <strong>and</strong> verify that the fiber-optic <strong>and</strong>/or metallic cables are<br />

installed as assigned.<br />

If not, change administration to remove the DS1 converter complex from<br />

the SNI’s fiber link:<br />

1. Enter list fiber-link to locate the fiber with this SNI as an<br />

endpoint<br />

2. Enter remove fiber-link to remove the fiber<br />

3. Enter add fiber-link to add the fiber back, without assigning the<br />

DS1 converter complex<br />