REM-OFF (Remote Office)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

REM-OFF MIN<br />

WRN<br />

An instance of this MO (REM-OFF) is associated with every Remote Office box that is<br />

administered on the switch. This MO monitors keep-alive <strong>and</strong> periodic PING <strong>test</strong> failures.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 223: REM-OFF Error Log Entries<br />

Error Type Aux<br />

Data<br />

Notes:<br />

a. Error Type 1: a PING <strong>test</strong> to the Remote Office has failed <strong>and</strong> a MINOR alarm has been<br />

raised. When this <strong>error</strong> is logged, as many as 26 endpoints associated with that Remote<br />

Office <strong>and</strong> several H.323 signaling groups could be out of service.<br />

b. Error Type 257: The response to a keep-alive update request exceeded the time limit for an<br />

endpoint. The <strong>error</strong> is a log-only <strong>error</strong>. It is not possible to determine which entity has failed.<br />

The aux data associated with this <strong>error</strong> indicates whether the endpoint that failed to<br />

respond was a DCP, Analog, or Signaling Group type:<br />

● 1096 = Analog Line<br />

● 1095 = DCP Line<br />

Associated<br />

Test<br />

● 6179 = H.323 Signaling Group<br />

ping node-name node-name |<br />

ip-address location<br />

Alarm<br />

Level<br />

On/Off<br />

Board<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Recommended Action<br />

There are no dem<strong>and</strong> <strong>test</strong>s for REM-OFF. Use ping ip-address or ping node-name to<br />

ping the Remote Office.<br />

810 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Remote Office<br />

1 (a) MIN OFF ping node-name node-name<br />

ping ip-address addr<br />

257 (b) Log only OFF ping node-name node-name<br />

ping ip-address addr