UDS1-BD (UDS1 Interface Circuit Pack)<br />

MO Name in<br />

Log<br />

UDS1-BD MAJ<br />

MIN<br />

The UDS1 Interface circuit pack provides an interface to the DS1 facility.<br />

The maintenance strategy for the TN464 UDS1 Interface circuit pack (UDS1-BD) is very similar<br />

to the maintenance strategy for the TN767 DS1 Interface circuit pack (DS1-BD). The same<br />

comm<strong>and</strong>s are used for administering <strong>and</strong> <strong>test</strong>ing the boards. The differences in maintenance<br />

strategy between the boards are due to the UDS1 circuit pack’s direct interface to the Packet<br />

bus which is used for ISDN-PRI signaling (ISDN-PLK). While both the TN464 <strong>and</strong> TN767 can<br />

support ISDN-PRI B-Chels, ISDN-PRI D-chel signaling applications require a TN464 UDS1<br />

circuit pack. See the following table for a list of USD1 Interface circuit packs:<br />

Circuit Pack<br />

Code<br />

Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

<strong>test</strong> board location l UDS1 Interface Circuit Pack<br />

WRN <strong>test</strong> board location<br />

24- Chel 32- Chel Tie Trunk<br />

Signaling<br />

TN2242 X X X<br />

TN464C/D/E/F<br />

TN464GP<br />

CO Trunk<br />

Signaling<br />

DID Trunk<br />

Signaling<br />

Note:<br />

Note: For information about other DS1 circuit packs, see DS1-BD (DS1 Interface Circuit<br />

Pack).<br />

The UDS1 maintenance strategy includes logging inline <strong>error</strong>s reported by the UDS1 Interface<br />

circuit pack, running <strong>test</strong>s for <strong>error</strong> diagnosis <strong>and</strong> recovery, <strong>and</strong> raising or clearing maintenance<br />

alarms.<br />

The TN464F or later circuit pack combined with an 120A1 CSU module forms an Enhanced<br />

Integrated CSU. The 120A1 CSU module, when combined with the functionality provided by the<br />

TN464F hardware <strong>and</strong> firmware, <strong>and</strong> switch software, provides functionality equivalent to an<br />

external st<strong>and</strong>-alone ESF T1 CSU. The 120A1 CSU module connects to the TN464F circuit<br />

pack on the I/O connector panel on the back of the port carrier. The CSU module thus becomes<br />

an integrated part of the system. Throughout the document, the term 120A1 will mean a 120A1<br />

or higher suffix CSU module.<br />

1022 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

OPS Line<br />

Signaling<br />

X X X X X X<br />

(24-chl only)<br />

TN2464 X X X X X X