o. Error Type 3840-4095: Certain ISDN-BRI cause <strong>codes</strong> are logged by switch software. The<br />

cause code can be determined from the following formula:<br />

If the Error Type is greater than 3968, then the ISDN-BRI cause code is equal to the Error<br />

Type minus 3968. This code was sent to the endpoint by the switch.<br />

If the Error Type is less than 3968, then the ISDN-BRI cause code is equal to the Error<br />

Type minus 3840. This code was sent to the switch by the endpoint.<br />

A description of the various ISDN-BRI cause values is contained in Table 60: ISDN-BRI<br />

CAUSE VALUES; (BRI-SET/ASAI-ADJ Error Log Notes). This table also contains<br />

recommended actions associated with the cause value. In addition, the Aux Data field of<br />

the Error Log entry contains additional diagnostic information.<br />

p. Error 3847: sets on the port do not support level 3 initialization. Consult the set service<br />

documentation.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

1. D = Destructive; ND = Nondestructive<br />

Long Test<br />

Sequence<br />

Note:<br />

a. Execute <strong>test</strong> port long location, <strong>and</strong> review the results of the BRI Port Local LAN<br />

Looparound Test (#618) to verify the repair.<br />

232 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

D/ND 1<br />

Signaling Link Status Test (#626) X X ND<br />

BRI XID Test (#628) X X ND<br />

BRI Layer 3 Query Test (#629) X ( a ) X ( a ) ND<br />

BRI Remote Loopback Test (#627) X ( a ) ND<br />

BRI Set Audits Test (#630) X ( a ) X ( a ) ND