19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 472: VC Summer Port Local TDM Looparound Test (#1100) 2 of 2<br />

Error<br />

Code<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. If this result occurs repeatedly, reset the circuit pack if the other<br />

ports are idle.<br />

2. Rerun the <strong>test</strong>.<br />

3. If this result occurs again, replace the circuit pack.<br />

2012<br />

2100<br />

2103<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong>.<br />

Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

The system could not make the conference connection for the <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

Any FAIL The TDM Loopoaround <strong>test</strong> or the Conference Circuit <strong>test</strong> failed.<br />

1. Replace circuit pack.<br />

PASS The VC Summer Port Local TDM Loopback <strong>test</strong> passed.<br />

VC DSP Port NPE Crosstalk Test (#1103)<br />

This <strong>test</strong> is destructive.<br />

The VC DSP Port NPE Crosstalk Test verifies that this port’s Network Processor Element (NPE)<br />

chel talks on the selected time slot <strong>and</strong> never crosses over to time slots reserved for other<br />

connections. If the NPE is not working correctly, one-way <strong>and</strong> noisy connections may be<br />

observed. This <strong>test</strong> is part of the port’s long <strong>test</strong> sequence <strong>and</strong> takes approximately 20 to 30<br />

seconds to complete.<br />

This <strong>test</strong> runs on VC-DSPPT (Voice Conditioner DSP Port).<br />

1560 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!