SNI Destructive Facility Off-Board Test (#756)<br />

SNI Destructive Facility Off-Board Test (#756)<br />

This <strong>test</strong> is destructive.<br />

The SNI runs a destructive looparound of the on- <strong>and</strong> off-board looparounds. This <strong>test</strong> returns<br />

the result of the off-board looparound, while Test 757 returns the result of the on-board<br />

looparound. For SNI-to-SNI fiber links, this <strong>test</strong> is run on both SNI circuit pack endpoints of the<br />

fiber link.<br />

The <strong>test</strong> runs on the following maintenance objects:<br />

● FIBER-LK (Fiber Link)<br />

● SNI-BD (SNI Circuit Pack)<br />

Table 435: SNI Slot / Error Type<br />

Specified SNI Slot Error Type<br />

2 1<br />

3 257<br />

4 513<br />

5 769<br />

6 1025<br />

7 1281<br />

8 1537<br />

9 1793<br />

13 2049<br />

14 2305<br />

15 2561<br />

16 2817<br />

17 3073<br />

18 3329<br />

19 3585<br />

20 3841<br />