4. Enter display alarms <strong>and</strong> determine the location of the circuit pack with the alarmed<br />

GPTD-PT, DTMR-PT, or GPTD-PT.<br />

Run <strong>test</strong> board location l r 3 for that circuit pack.<br />

If this does not clear the TTR Level alarm, replace the Tone Detector or Call Classifier<br />

circuit pack with the alarmed GPTD-PT, DTMR-PT, or CLSFY-PT.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 272: TTR-LEV Error Log Entries<br />

Error<br />

Type<br />

1 (a) 1<br />

Aux<br />

Data<br />

Associated Test Alarm Level On/Off<br />

Board<br />

2 (b) 2 WRN<br />

(See message below)<br />

3 (c) 3<br />

WARNING: The TTR-LEV Alarm is upgraded to MAJOR if the Base Tone Generator is set to<br />

12 (France).<br />

Notes:<br />

a. Error Type 1: does not indicate a current <strong>error</strong> condition. It indicates that the number of<br />

DTMR ports in service was below the administered threshold, but is now equal to or greater<br />

than the threshold. These <strong>error</strong>s are typically generated during boot time or other<br />

transitional states when the ports are being brought into service.<br />

b. Error Type 2: the total number of DTMR ports currently in service is below the administered<br />

threshold. To clear the alarm, see Repair Procedure for TTR-LEV.<br />

c. Error Type 3: does not indicate a current <strong>error</strong> condition. It indicates that the number of<br />

GPTD ports in service was below the administered threshold, but is now equal to or greater<br />

than the threshold. These <strong>error</strong>s are typically generated during boot time or other<br />

transitional states when the ports are being brought into service.<br />

OFF<br />

4 (d) 4 WRN OFF<br />

5 (e) 5<br />

6 (f) 6 WRN OFF<br />

7 (g) 7 MAJ OFF<br />

8 (h) 8 MIN OFF<br />

9 (i) 9 MIN OFF<br />

1020 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />