Error log entries <strong>and</strong> recommended actions<br />

Table 200: OPS-LINE Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> station ext<br />

15 (b) Any Port Audit <strong>and</strong> Update<br />

Test (#36)<br />

18 (c) 0 busyout station<br />

ext<br />

WRN OFF release station ext<br />

130 (d) WRN ON <strong>test</strong> station ext<br />

1281 Conference Circuit Test<br />

(#7)<br />

MIN ON <strong>test</strong> station ext l r 4<br />

1537 NPE Crosstalk Test (#6) MIN ON <strong>test</strong> station ext l r 3<br />

1793 (e) <strong>test</strong> board location l<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description, <strong>and</strong> follow its procedures.<br />

b. Error Type 15: software audit <strong>error</strong> which does not indicate a hardware malfunction. Run<br />

the short <strong>test</strong> sequence <strong>and</strong> investigate associated <strong>error</strong>s (if any).<br />

c. Error Type 18: the DS1 OPS Line was busied out by busyout station ext. No calls<br />

can be made on this line. Release the line with release station ext.<br />

d. Error Type 130: the circuit pack was removed or was insane for more than 11 minutes. To<br />

clear the <strong>error</strong>, reinsert or replace the circuit pack.<br />

e. Error Type 1793 there is a problem with the DS1 Interface circuit pack. Because there is no<br />

<strong>error</strong> against the OPS-LINE port, no alarm is raised against the OPS-LINE port. However,<br />

there should be <strong>error</strong>s logged against the DS1 Interface circuit pack. Look for DS1-BD/<br />

UDS1-BD <strong>error</strong>s in the Error Log, <strong>and</strong> follow the procedures in DS1-BD (DS1 Interface<br />

Circuit Pack).<br />

696 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers