Table 486: Far CSU Loopback Test (#1213) 3 of 3<br />

Error<br />

Code<br />

2<br />

3<br />

Test<br />

Result<br />

One-Way Span Test (#1214)<br />

This <strong>test</strong> is destructive.<br />

For documentation purposes, the term DS1 applies to the following:<br />

DS1 Interface circuit packs<br />

DS1 Interface media modules<br />

UDS1 circuit packs.<br />

One-Way Span Test (#1214)<br />

FAIL The far CSU Loopback <strong>test</strong> was not set up properly. The DS1 Interface<br />

circuit pack could not put the far-end CSU into loopback mode.<br />

The far CSU Loopback <strong>test</strong> was not set up properly. The framed 3-in-24<br />

<strong>test</strong> pattern, generated by the DS1 Interface circuit pack <strong>and</strong> looped back<br />

through the far-end CSU, could not be detected by the DS1 circuit pack.<br />

1. Enter <strong>test</strong> ds1-loop location<br />

far-csu-loopback-<strong>test</strong>-begin<br />

2. If the Far CSU Loopback <strong>test</strong> continues to fail with this <strong>error</strong> code,<br />

the problem could be with the DS1 board, the far-end CSU<br />

equipment, or somewhere in between. Run <strong>test</strong> ds1-loop<br />

location cpe-loopback-jack-<strong>test</strong>-begin to see if the CPE<br />

Loopback Jack <strong>test</strong> that is closer to the DS1 board is successful.<br />

If a CPE loopback jack device is not being used, run <strong>test</strong><br />

ds1-loop location ds1/csu-loopback-<strong>test</strong>s to see if the<br />

closer loopback <strong>test</strong>s succeed. If the closer loopback <strong>test</strong> fails, follow<br />

the maintenance strategy associated with that loopback<br />

PASS The Far CSU Loopback <strong>test</strong> has successfully began executing. The <strong>test</strong><br />

runs until <strong>test</strong> ds1-loop location end-loopback/span-<strong>test</strong> is<br />

entered.<br />

1. Enter release board location to release the trunks <strong>and</strong> ports.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures.<br />