19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SP-REG-M (Survivable Processor-Main)<br />

MO Name in Log Alarm<br />

Level<br />

SP-REG-M MAJ<br />

MIN<br />

SP-REG-M (Survivable Processor-Main)<br />

The Survivable Processor object monitors keep-alive message between the main server <strong>and</strong><br />

the survivable processor, which can be either:<br />

● Local Survivable Processor (LSP)<br />

Initial Comm<strong>and</strong> to Run Full Name of MO<br />

● Enterprise Survivable Server (ESS)<br />

The server exchanges keep-alive messages with each of the survivable processors. If the<br />

server does not receive a predetermined number of those messages, both the server <strong>and</strong> the<br />

survivable processor alarm.<br />

If an LSP does not register with an ESS, it registers with either the main server or another ESS<br />

<strong>and</strong> alarms are not raised.<br />

Possible causes for SP-REG-M alarms include:<br />

● The network is down.<br />

● The server or survivable processor administration is incorrect.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 238: SP-REG-M Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated<br />

Test<br />

None Survivable Processor-Main<br />

Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

1 (a) 0-63 MIN OFF status ess-cluster<br />

769 (b) 0 MAJ OFF<br />

Issue 5 May 2009 879