RDIG-STA (Remote Digital Station)<br />

k. Error Type 2305 with Aux Data 32770: the station went off-hook while it was in the<br />

ready-for-service state. Use the status station comm<strong>and</strong> to determine the state of the<br />

station. The off-hook should have moved the station to ready-for-service. No action is<br />

necessary.<br />

Error Type 2305 with Aux Data 40967: an off-board warning was generated due to a<br />

problem with the link to the voice terminal. This can be ignored if no user complaints are<br />

received. Otherwise, make sure the voice terminal is connected, check for defective<br />

wiring, check for a defective voice terminal, <strong>and</strong> move the voice terminal to a jack that is<br />

closer to the switch (in terms of feet of wiring between the jack <strong>and</strong> the switch). If the<br />

problem persists, replace the circuit pack. Once the problem has been resolved, the alarm<br />

disappears after a predetermined amount of time.<br />

l. Error Type 2817: the endpoint caused a large number of control channel messages to be<br />

sent to the switch within a short period of time (50 or more CCMS uplinks within 10<br />

seconds). The station will be taken out-of-service for 30 seconds due to the hyperactivity.<br />

This may be completely normal during heavy traffic periods.<br />

m. Error Type 3840 with Aux Data 40965: no terminal is connected to the board. No<br />

maintenance action is required. This is also the code that is generated when the link<br />

between the circuit pack <strong>and</strong> the voice terminal is successfully reset. No action is<br />

necessary.<br />

Error Type 3840 with Aux Data 40989: Indicates an uplink message has been logged<br />

indicating that the Electric Power Feed (EPF) is on with no load on it. No action is<br />

necessary.<br />

n. Error Type 3841: the circuit pack’s message buffer is full. This may be caused by having<br />

many display phones with heavy traffic connected to the circuit pack. No action is<br />

necessary.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

1. D = Destructive; ND = Nondestructive<br />

Long Test<br />

Sequence<br />

D/ND 1<br />

Digital Line Electronic Power Feed Test (#11) X ND<br />

Digital Station Lamp Update (#16) X X ND<br />

Digital Station Audits Test (#17) X X ND<br />