19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PS-RGEN (Power Supply Ring Generator)<br />

G650<br />

MO Name in Log Alarm<br />

Level<br />

PS-RGEN MAJ<br />

MIN<br />

Initial Comm<strong>and</strong> to Run Full name of MO<br />

The PS-RGEN maintenance object monitors the ringing voltage of each 655A power supply.<br />

The TN2312BP IPSI uses the ring detection circuit on the 655A to monitor ring voltage for the<br />

G650. When the TN2312BP IPSI is used in an MCC1 or SCC1, the ring detector on the tone<br />

clock monitors ringing.<br />

When the G650 is equipped with two power supplies, the 655A power supply on the left (slot 0)<br />

is the primary power supply (master) <strong>and</strong> the 655A power supply on the right (slot 15) is the<br />

secondary power supply. In normal operation, the primary 655A provides ringing for the G650. If<br />

the primary 655A is unable to provide ringing to the G650 because it has failed or because of a<br />

comm<strong>and</strong> from the TN2312BP IPSI, the secondary 655A connects ringing to the backplane<br />

using an arbitration lead.<br />

Normally the ring voltage LED (#5) on the left power supply is ON <strong>and</strong> the ring voltage LED on<br />

the right power supply is OFF. This changes momentarily when the ringer interchange <strong>test</strong> is<br />

run. The ring voltage LED will only remain lit on the right power supply when there is a power<br />

supply failure of the left h<strong>and</strong> supply or the left h<strong>and</strong> supply is removed.<br />

Only one 655A power supply provides ringing voltage to the backplane. The other power supply<br />

ring voltage output is isolated from the backplane through a relay contact.<br />

Refer to Figure 66: G650 Cabinet Environmental Hardware Components for further<br />

information.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 218: PS-RGEN Error Log Entries 1 of 2<br />

Error<br />

Type<br />

1 0<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

1 (a) Ring generator<br />

interchange <strong>test</strong><br />

(#1539)<br />

<strong>test</strong> board location Power Supply Ring Generator<br />

On/Off<br />

Board<br />

Recommended Action<br />

MAJ ON <strong>test</strong> environment location<br />

1<br />

MIN <strong>test</strong> board location long<br />

792 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

1 of 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!