Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 460: Packet Interface Maintenance Looparound Test (#886) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

1–5 FAIL<br />

(cont’d)<br />

Fail Code 5: old firmware not compatible with new software.<br />

1. Verify the IPSI circuit pack’s firmware vintage <strong>and</strong> download the<br />

new firmware if appropriate.<br />

Note: At<br />

Note:<br />

the <strong>Avaya</strong> support site(http://support.avaya.com),<br />

search on “Firmware Compatibility Matrix” to find the<br />

la<strong>test</strong> firmware vintage. Be sure to review the ‘ReadMe’<br />

file that accompanies the firmware image for any<br />

interactions with a particular software release.<br />

2. The firmware image on the IPSI circuit pack may have been<br />

corrupted. Download <strong>and</strong> replace the firmware image.<br />

3. Retry the comm<strong>and</strong>.<br />

PASS The Packet Interface module on the IPSI circuit pack <strong>and</strong> its interface<br />

are functioning properly. If the system is unable to place calls on PNs<br />

served by this IPSI, then:<br />

1. Check for PKT-BUS (Packet Bus) <strong>error</strong>s, <strong>and</strong> solve those <strong>error</strong>s<br />

first.<br />

2. Check for <strong>error</strong>s in the PN where calls cot be completed, <strong>and</strong><br />

solve those <strong>error</strong>s.<br />

3. Check every other circuit pack connected to the packet bus in the<br />

same cabinet. Packet bus failures are likely to be caused by a<br />

faulty circuit pack connected to the backplane or bent pins on the<br />

back plane.<br />

4. Check the IPSI circuit pack’s Packet Interface module that serves<br />

this PN for <strong>error</strong>s, <strong>and</strong> resolve these <strong>error</strong>s.<br />

5. If <strong>error</strong>s continue, escalate.<br />

NO<br />

BOARD<br />

Description / Recommendation<br />

The IPSI circuit pack’s Packet Interface module is assigned but is not<br />

detected as being physically present.<br />

1. If the IPSI circuit pack is present, replace it.<br />

2. If the IPSI circuit pack is not present, insert a TN2312AP IPSI<br />

circuit pack in the assigned slot, <strong>and</strong> rerun the <strong>test</strong>.<br />