Communication Manager Maintenance Object Repair Procedures<br />

2. Remove the ATM-INTF administration <strong>and</strong> re-administer the slot (change circuit-pack)<br />

to match the circuit-pack that is physically present in this slot.<br />

f. Error Type 131: An ATM-EI circuit pack has been removed from the slot for 5 minutes.<br />

1. Insert the ATM-EI circuit pack into its administered slot.<br />

2. Another way to resolve or prevent this alarm is to remove the ATM-EI administration.<br />

See Basic ATM PNC Administration, then remove the ATM-INTF administration<br />

(change circuit-pack).<br />

It is possible that the ATM-EI could be held in reset by the PN’s Maintenance board <strong>and</strong> is<br />

not inserted in the system.<br />

3. Try <strong>test</strong> maint P long on the maintenance board in the same PN.<br />

g. Error Type 257: Expansion Interface Control Chel Test (#316) failed (board cot<br />

communicate on the TDM bus control chel). Follow the suggested <strong>test</strong> procedures.<br />

Error Type 258: The archangel is out of sequence (Aux Data indicates Angel number).<br />

Error type 259: The expansion archangel link (EAL) to the active ATM-EI board is down.<br />

See SYS-LINK (System Links).<br />

h. Error Type 513: The ATM Crosstalk <strong>test</strong> failed. The board is either writing to or reading<br />

from a TDM time slot that is not allocated to the board.<br />

1. Test the board (<strong>test</strong> board location), <strong>and</strong> follow the procedures suggested for<br />

this <strong>test</strong>. In r<strong>and</strong>om <strong>test</strong>s of a single DSP during low or high traffic, the same DSP can<br />

be <strong>test</strong>ed more than once.<br />

i. Error Types 769 <strong>and</strong> 770: are board-degraded alarm <strong>error</strong>s that result when the ATM<br />

switch is sending corrupted cells or excessive AAL/LAPD retransmissions (off-board ATM<br />

cell corruption <strong>error</strong>s). These <strong>error</strong>s indicate the detection of a problem in h<strong>and</strong>ling ATM<br />

cells that are received from the fiber interface.<br />

Aux Data for these Error Types:<br />

Error Type Aux Data Description<br />

769 34 Excessive AAL-5 retransmission requests<br />

769 35 Excessive LAPD retransmission requests<br />

770 25 Uncorrectable ATM cell headers – threshold<br />

771 26 VPI, VCI pair unknown<br />

The problem is most likely not on the ATM-EI circuit pack reporting the <strong>error</strong>s, but it could<br />

be due to one or more of the following reasons:<br />

● The fiber is not snugly connected to either the board or the ATM switch.<br />

● The PN’s packet bus is corrupting the cells. See PKT-BUS (Packet Bus) (Aux Data 35<br />

only).<br />

132 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers