Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 344: Misframe Alarm Inquiry Test (#145)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time. This may<br />

be due to hyperactivity.<br />

1. Enter display <strong>error</strong>s<br />

2. Check the Error Log for Error Type 1538. If Error Type 1538<br />

appears in the <strong>error</strong> log for this board, see Hyperactive DS1/UDS1<br />

Interface Circuit Pack/Media Module for the repair procedures.<br />

Otherwise, retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

ANY FAIL The DS1 board detected <strong>error</strong>s in the received framing bits pattern. The<br />

Error Code value is the number of misframes detected since the last<br />

misframe alarm inquiry <strong>test</strong>. Major bit <strong>and</strong> minor bit <strong>error</strong> rate (Error<br />

Types 2561 <strong>and</strong> 2817) <strong>error</strong>s often accompany misframe alarms.<br />

Clearing the cause of these <strong>error</strong>s may clear the misframes which are<br />

occurring.<br />

1. Enter list measurement ds1-log location to read the<br />

<strong>error</strong> seconds measurement.<br />

2. If the DS1/UDS1 circuit pack or media module connects to a T1<br />

network facility or to another switch, see T1 Network Facility<br />

Procedures<br />

0 NO<br />

BOARD<br />

3. If the DS1/UDS1 circuit pack or media module connects to a<br />

line-side terminating device such as a PRI terminal adapter, see<br />

Line-side Terminating Device Procedures<br />

PASS No Misframe Alarm is detected on the DS1 board.<br />

See NO BOARD for the repair procedures<br />

1256 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers