Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 320: Modem Pool Conference Test (#97) 3 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

4000 ABORT System resources needed to complete the <strong>test</strong> could not be allocated.<br />

This usually means the conversion resource or other hardware needed<br />

for the <strong>test</strong> was in use.<br />

1. Wait 1 minute <strong>and</strong> run the <strong>test</strong> again.<br />

2. If the same <strong>error</strong> occurs, enter status port to determine whether<br />

the Modem Pool conversion resource is in use.<br />

3. If the conversion resource is in use, <strong>and</strong> it is absolutely necessary<br />

to <strong>test</strong> it, the call must be dropped by entering busyout port<br />

location against the conversion resource. Run the <strong>test</strong> again.<br />

4. If the same <strong>error</strong> occurs while the conversion resource is idle,<br />

busyout both Modem Pool conversion resources on the TN758<br />

Pooled Modem circuit pack containing the conversion resource<br />

under <strong>test</strong>. Run the <strong>test</strong> again.<br />

5. If the <strong>test</strong> continues to abort, replace the Pooled Modem circuit<br />

pack <strong>and</strong> re<strong>test</strong>.<br />

65515 ABORT System resources required for this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. Enter <strong>test</strong> port location long for the port on which the <strong>test</strong><br />

aborted. If any <strong>test</strong> aborted or failed, follow the recommended<br />

repair procedures for the appropriate port type (for example,<br />

ANL-LINE (8-Port Analog Line), DIG-LINE (Digital Line)).<br />

FAIL This <strong>error</strong> is internal to the Pooled Modem circuit pack <strong>and</strong> does not<br />

involve external equipment or interfaces.<br />

1. Busyout both of the TN758 Pooled Modem conversion resources<br />

on the circuit pack containing the failing conversion resource.<br />

2. If the <strong>test</strong> continues to fail, replace the Pooled Modem circuit pack<br />

<strong>and</strong> re<strong>test</strong>.<br />

1194 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />