Table 347: TDM Bus Clock Slip Inquiry Test (#149) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

TDM Bus Clock Slip Inquiry Test (#149)<br />

ABORT The system could not allocate the necessary resources for the <strong>test</strong><br />

1. Retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

1001 ABORT Internal <strong>error</strong>.<br />

1. Retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

1005 ABORT This <strong>test</strong> does not run on a TN2182, TN2312, or TN8412 circuit packs.<br />

This <strong>error</strong> can be ignored.<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT System resources required to run this <strong>test</strong> are not available<br />

1. Retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

1 of 2<br />