19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Slip Alarm Inquiry Test (#144)<br />

Slips occur when the transmitter <strong>and</strong> receiver are not running at precisely the same clock rate.<br />

The DS1/UDS1 Interface circuit pack or media module can detect both positive <strong>and</strong> negative<br />

slips on the DS1 facility. The Slip Alarm Inquiry Test displays the total number of slips that have<br />

occurred on a DS1 link if there are any.<br />

Every trunk or port of the DS1 board remains in the in-service state. If the DS1 board supplies<br />

the system synchronization source, the MINOR alarm will initiate a synchronization source<br />

switch. See TDM-BUS (TDM Bus) <strong>and</strong> SYNC (Port Network Synchronization) for details.<br />

This <strong>test</strong> is run on the following maintenance objects:<br />

● DS1-BD (DS1 Interface Circuit Pack)<br />

● MAPD-BD (MAPD Interface Circuit Pack)<br />

● MG-DS1 (DS1 Interface Media Module)<br />

● UDS1-BD (UDS1 Interface Circuit Pack)<br />

Table 343: Slip Alarm Inquiry Test (#144) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Check the Error Log for Error Type 1538. If Error Type 1538<br />

appears in the <strong>error</strong> log for this board, see Hyperactive DS1/<br />

UDS1 Interface Circuit Pack/Media Module for the repair<br />

procedures. Otherwise, retry the <strong>test</strong> at 1-minute intervals up to 5<br />

times.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1254 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />