RC-BD (Radio Controller Board)<br />

MO Name<br />

in Log<br />

Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

RC-BD MIN <strong>test</strong> board location long Radio Controller Board<br />

WRN <strong>test</strong> board location<br />

The RC-BD maintenance object is inserted into the system whenever the TN789 RC circuit<br />

pack is administered <strong>and</strong> physically inserted into a slot. Each RC circuit pack is maintained as a<br />

separate MO.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 220: RC-BD Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> board location<br />

1 (b) 0 Circuit pack<br />

removed or SAKI<br />

Test failed (#53)<br />

18 (c) 0 busyout<br />

station<br />

extension<br />

23 (d) WRN OFF<br />

125 (e) WRN ON<br />

130 (f) WRN OFF<br />

257 (g) Control Channel<br />

Looparound Test<br />

(#52)<br />

MIN ON <strong>test</strong> board location<br />

WRN OFF release board loc<br />

MIN ON <strong>test</strong> board location r 20<br />

513 (h) MIN ON <strong>test</strong> board location r 2<br />

769 (i)<br />

1025 (j) NPE Audit (#50)<br />

798 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />