CLSFY-PT (Call Classifier Port)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

CLSFY-PT MAJ<br />

MIN<br />

WRN<br />

The TN744 Call Classifier is a service circuit pack that provides specialized tone detection<br />

capabilities to support the Outbound Call Management (OCM) <strong>and</strong> Inbound Call Management<br />

(ICM) features. The TN744 supports both A-law <strong>and</strong> Mu-law comp<strong>and</strong>ing.<br />

The TN744 has eight ports (CLSFY-PTs), each capable of supporting call classification,<br />

touch-tone reception <strong>and</strong> MFC-tone generation <strong>and</strong> detection. The CLSFY-PT MO implements<br />

a set of <strong>test</strong>s designed to ensure proper operation of the Call Classifier.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 73: CLSFY-PT Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm Level On/Off<br />

Board<br />

<strong>test</strong> port location Call Classifier Port<br />

Recommended Action<br />

1 any Tone Detector Audit/<br />

Update Test (#43)<br />

MAJ / MIN (a) ON <strong>test</strong> port location r 2<br />

18 busyout port WRN OFF release port location<br />

257 (b) 17666 Tone Detector Audit/<br />

Update Test (#43)<br />

513 (c) any Tone Detection<br />

Verification Test<br />

(#42)<br />

MAJ / MIN (a) ON <strong>test</strong> port location r 3<br />

MAJ / MIN (a) ON <strong>test</strong> port location r 3<br />

Notes:<br />

a. A major alarm is raised if the total number of call classifier ports currently in-service is less<br />

than or equal to 1/2 of the administered threshold number. For major or minor alarm, run the<br />

short <strong>test</strong> sequence on the alarmed port <strong>and</strong> follow the <strong>error</strong> code procedures for the<br />

individual <strong>test</strong>s.<br />

The in-service threshold number for alarming call classifier ports is administered using the<br />

change system-parameters maintenance.<br />

274 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers