19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 486: Far CSU Loopback Test (#1213) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1015 ABORT Ports on the DS1 Interface circuit pack have not been busied out to<br />

out-of-service.<br />

1. Enter busyout board location to put all trunks or ports of the<br />

DS1 Interface circuit pack into the out-of-service state.<br />

2. Retry the comm<strong>and</strong>.<br />

1039 ABORT The DS1 Interface circuit pack is providing timing for the system. Executing<br />

this <strong>test</strong> could cause major system disruption.<br />

If the DS1 Interface circuit pack needs to be <strong>test</strong>ed, set the<br />

synchronization reference to another DS1 Interface circuit pack or to the<br />

Tone-Clock circuit with the following comm<strong>and</strong> sequence:<br />

1. disable synchronization-switch.<br />

2. set synchronization location.<br />

3. enable synchronization-switch.<br />

1950 ABORT Another loopback/span <strong>test</strong> is already executing on the DS1 board or the<br />

board is in a network requested loopback mode (Line loopback or Payload<br />

loopback). The <strong>error</strong> log will indicate whether a Customer Loopback Jack<br />

<strong>test</strong>, Far CSU Loopback <strong>test</strong>, or the One-Way Span <strong>test</strong> is executing or if<br />

the board is in line loopback or payload loopback mode. Only one<br />

long-duration loopback/span <strong>test</strong> can be active at a given time.<br />

If a loopback/span <strong>test</strong> is already active, that <strong>test</strong> must be deactivated with<br />

<strong>test</strong> ds1-loop location end-loopback/span-<strong>test</strong> in order to<br />

run this <strong>test</strong>.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Check for board hyperactivity. See Hyperactive DS1/UDS1 Interface<br />

Circuit Pack/Media Module.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2 FAIL The far CSU Loopback <strong>test</strong> was not set up properly. The DS1 Interface<br />

circuit pack could not put the far-end CSU into loopback mode.<br />

1590 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 3

Hooray! Your file is uploaded and ready to be published.