Communication Manager Maintenance Object Repair Procedures<br />

e. Error Type 257: this is an inline <strong>error</strong> <strong>and</strong> can only be resolved over time. This <strong>error</strong><br />

indicates that ringing voltage is absent.<br />

For media modules: If not resolved over time, replace the media module.<br />

For circuit packs:<br />

● If only 1 analog circuit pack in the system has this problem, replace the circuit<br />

pack.<br />

● If only analog circuit packs on a particular carrier have this <strong>error</strong>, the ringing<br />

generator may not be connected to this carrier.<br />

● If analog circuit packs on many carriers have this <strong>error</strong>, it is probably a problem<br />

with the ringing generator.<br />

f. Error Type 513:Test #48 can cause some terminal equipment to ring briefly during daily<br />

maintenance. If this disturbs the customer or the terminal equipment, disable it by setting<br />

the Tests field on the change station extension form to n. In some software<br />

releases, this also disables Tests #6, 7, 161, <strong>and</strong> 35.<br />

76 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers