Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

DSP Port TDM Looparound Test (#1380)<br />

This <strong>test</strong> sets up a loopback path from the TDM bus out to the NIC edge of the Media Processor<br />

<strong>and</strong> back to the TDM bus. The loopback is established by setting up the outbound IP connection<br />

to send IP packets to the MedPro’s own IP address. The tone generator places a <strong>test</strong> tone<br />

(440Hz) onto a timeslot. The timeslot is listened to by the Media Processor board. The tone is<br />

routed through the board’s DSP farm, where it may undergo transcoding to G.723, etc. The tone<br />

is looped back at the Network interface <strong>and</strong> back through the board where it is converted back<br />

into st<strong>and</strong>ard PCM. The tone is placed onto a TDM timeslot <strong>and</strong> detected by a tone detector<br />

port. The <strong>test</strong> passes if 440Hz is reported by the tone detector<br />

This <strong>test</strong> runs on MEDPROPT (MEDPRO DSP PORT).<br />

Table 522: DSP Port TDM Looparound Test (#1380) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1002 ABORT The system could not allocate time slots for the <strong>test</strong>. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service due<br />

to TDM-BUS <strong>error</strong>s. A system is considered under heavy traffic when the<br />

Call Processing Occupancy is greater than 50% or when the System<br />

Management <strong>and</strong> the Call Processing Occupancies together exceed<br />

65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display <strong>error</strong>s <strong>and</strong> resolve any TDM-BUS (TDM Bus)<br />

<strong>error</strong>s.<br />

3. If the system has no TDM-BUS <strong>error</strong>s <strong>and</strong> is not h<strong>and</strong>ling heavy<br />

traffic, retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1003 ABORT The system could not allocate a tone receiver for the <strong>test</strong>. The system<br />

may be oversized for the number of Tone Detectors present, or some<br />

Tone Detectors may be out of service.<br />

1. Enter list measurements tone-receiver to see information<br />

regarding the system’s tone receivers.<br />

2. Resolve any TTR-LEV (TTR Level) <strong>error</strong>s.<br />

3. Resolve any TONE-PT (Tone Generator) <strong>error</strong>s.<br />

4. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1014 ABORT Board not inserted.<br />

1654 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />