VC-BD (Voice Conditioner Circuit Pack)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

VC-BD MAJ<br />

MIN<br />

! CAUTION:<br />

CAUTION: If the TN788 Voice Conditioner circuit pack (VC-BD) is not Vintage 2 or later, it<br />

must be replaced.<br />

The TN788 Voice Conditioner circuit pack (VC-BD) is a service circuit pack that provides<br />

conditioning for the audio signals from multimedia equipment based on the CCITT H.221<br />

st<strong>and</strong>ard. The TN788 trans<strong>codes</strong>, gain adjusts, <strong>and</strong> bridges the audio bit streams demultiplexed<br />

by the TN787 (MMI) circuit pack <strong>and</strong> transmits encoded, exclusive audio conference sums onto<br />

the TDM bus so that the MMI can multiplex the audio, video, <strong>and</strong> data streams for the H.221<br />

endpoints.<br />

Error log entries <strong>and</strong> recommended actions<br />

<strong>test</strong> board location l Voice Conditioner circuit pack<br />

WRN 1 <strong>test</strong> board location<br />

1. See XXX-BD (Common Port Circuit Pack/Media Module).<br />

Table 275: VC-BD Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> board location<br />

1 (b) Any None MIN ON<br />

18 (c) 0 busyout board location WRN OFF release board location<br />

257 (d) Any Control Chel Looparound Test<br />

(#52)<br />

513 (e) 4352-<br />

4357<br />

769 (f) 4358<br />

1025 (g) 4363 NPE Audit Test (#50)<br />

1281 (h) Any SAKI Sanity <strong>test</strong> (#53) MAJ ON<br />

1293 -<br />

1294 (i)<br />

46088-<br />

46096<br />

SAKI Sanity <strong>test</strong> (#53) MIN ON<br />

1538 (j) 46082 MIN ON<br />

MIN ON <strong>test</strong> board location r 20<br />

1052 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers