Table 128: FW-STDL Error Log entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated<br />

Test<br />

257 4 WRN OFF <strong>test</strong> firmware station-download<br />

257 12 WRN OFF <strong>test</strong> firmware station-download<br />

257 13 WRN OFF <strong>test</strong> firmware station-download<br />

257 14 WRN OFF <strong>test</strong> firmware station-download<br />

257 15 WRN OFF <strong>test</strong> firmware station-download<br />

258 (b) 5 WRN OFF <strong>test</strong> firmware station-download<br />

513 (c) 4 MIN OFF <strong>test</strong> firmware station-download<br />

513 8 MIN OFF <strong>test</strong> firmware station-download<br />

513 11 MIN OFF <strong>test</strong> firmware station-download<br />

513 13 MIN OFF <strong>test</strong> firmware station-download<br />

513 14 MIN OFF <strong>test</strong> firmware station-download<br />

513 15 MIN OFF <strong>test</strong> firmware station-download<br />

Notes:<br />

a. Error Type 257: The problem originated with the target terminal. Resolve the alarm with the<br />

<strong>test</strong> firmware station-download comm<strong>and</strong>. The Aux Data values associated with<br />

Error Type 257 are described in Table 129: Error Type 257 Aux Data <strong>descriptions</strong>.<br />

Table 129: Error Type 257 Aux Data <strong>descriptions</strong> 1 of 2<br />

Aux Data Description<br />

Alarm<br />

Level<br />

On/Off<br />

Board<br />

1 Terminal failed to erase its program flash.<br />

2 Target image file checksum is bad.<br />

3 Target image is incompatible with the terminal (<strong>Avaya</strong> 2420 DCP sets only).<br />

4 Target terminal rejected image as invalid.<br />

Recommended Action<br />

12 Target terminal fails to go into the download mode, timeout occurred.<br />

13 Station firmware download engine timed out waiting for download to<br />

complete.<br />

484 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />