Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 337: Loss of Signal Alarm Inquiry Test (#138) 3 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1301 FAIL The 120A CSU module or the 401A T1 sync splitter, or the 402A or 403A<br />

E1 synchronization splitter is not expected.<br />

The 120A CSU module or the 401A T1 sync splitter is not expected: The<br />

120A CSU module/T1 sync splitter is physically connected to the DS1/<br />

UDS1 board on the back of the port carrier, but the Near-End CSU Type<br />

field on the add ds1 screen has not been administered as integrated.<br />

1. If the 120A CSU module/T1 sync splitter is to be used, use change<br />

ds1 to set the Near-End CSU Type field to integrated. Otherwise,<br />

physically remove the 120A CSU module/T1 sync splitter from the<br />

back of the port carrier.<br />

2. Run the <strong>test</strong> again.<br />

The 402A or 403A E1 synchronization splitter is not expected: The 402A<br />

or 403A E1 synchronization splitter is physically connected to the DS1/<br />

UDS1 board on the back of the port carrier, but the E1 Sync-Splitter?<br />

field on the add ds1 screen has not been administered as y.<br />

1. If the 402A or 403A E1 synchronization splitter is to be used, use<br />

change ds1 to change the E1 Sync-Splitter field to y. Otherwise,<br />

physically remove the 402A or 403A E1 synchronization splitter from<br />

the back of the port carrier.<br />

2. Run the <strong>test</strong> again.<br />

1302 FAIL Attempting to use the 120A CSU module with a DS1/UDS1 circuit pack<br />

that is configured for 32-chel (2.048-Mbps) operation. The CSU module<br />

only works with a DS1/UDS1 board configured for 24-chel (1.544-Mbps)<br />

operation in the United States.<br />

1. If the 120A CSU module is to be used, physically remove the DS1/<br />

UDS1 circuit pack <strong>and</strong> reconfigure it for 24-chel (1.544-Mbps)<br />

operation.<br />

2. Reinsert the circuit pack <strong>and</strong> run the <strong>test</strong> again.<br />