Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 288: Digital Line Electronic Power Feed Test (#11) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The port<br />

may be busy with a valid call.<br />

1. Enter display port location to determine the station<br />

extension or attendant number of the port.<br />

2. Enter status station or status attendant to determine the<br />

service state of the port. If the port is in use, wait until it is idle<br />

before <strong>test</strong>ing. Attendants are always in use (off-hook) if the<br />

h<strong>and</strong>set is plugged in <strong>and</strong> the port is not busied out.<br />

3. If the port status is idle, then retry the comm<strong>and</strong> at 1-minute<br />

intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources for this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

PASS Electronic Power Feed <strong>test</strong> passed. The message to turn on the power<br />

to the station was successfully sent to the port.<br />

1. Although, except for the previous Internal system <strong>error</strong>, this <strong>test</strong><br />

never actually returns a FAIL result, it will log an <strong>error</strong> indicating the<br />

real results of the <strong>test</strong>. Check the Error Log for any entries with<br />

Error Types 767 or 769 after the <strong>test</strong> completes.<br />

2. If Error Type 767 appears in the Error Log, this indicates that the<br />

<strong>test</strong> sensed no problems with the power to the station. To verify that<br />

the station is powered up correctly, run a self-<strong>test</strong> on the station <strong>and</strong><br />

check that every feature button is operating.<br />

3. If Error Type 769 appears in the Error Log, this indicates some<br />

problem with the power to the station. Check for a short in the<br />

wiring, a damaged jack, a defective voice terminal, or an incorrect<br />

type of terminal.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for the repair procedures.<br />