Table 457: Automatic Transmission Test (#844-848) 2 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Automatic Transmission Test (#844-848)<br />

1002 ABORT The system could not allocate time slots for the <strong>test</strong>. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service<br />

due to TDM-BUS <strong>error</strong>s. A system is considered under heavy traffic<br />

when the Call Processing Occupancy is greater than 50% or when the<br />

System Management <strong>and</strong> the Call Processing Occupancies together<br />

exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display <strong>error</strong>s <strong>and</strong> resolve any TDM-BUS (TDM Bus)<br />

<strong>error</strong>s.<br />

3. If the system has no TDM-BUS <strong>error</strong>s <strong>and</strong> is not h<strong>and</strong>ling heavy<br />

traffic, retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1004 ABORT The port has been seized by a user for a valid call.<br />

1. Enter status trunk to determine when the port is available for<br />

<strong>test</strong>ing.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1005 ABORT Wrong trunk group type for this <strong>test</strong>. This <strong>error</strong> can be ignored.<br />

1115 ABORT The near end <strong>test</strong> line on the TN771 circuit pack could not be allocated.<br />

1. Enter status port <strong>and</strong> verify that the TN771 circuit pack is in<br />

service. Also verify that port 1 is administered <strong>and</strong> in service.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1900 ABORT Test completion message was not received from the TN771 circuit pack.<br />

1. Test the TN771 circuit packs.<br />

1901 ABORT TN771 sent wrong response for this <strong>test</strong>.<br />

1. Verify that the trunk is administered properly.<br />