BRI Set Audits Test (#630)<br />

BRI Set Audits Test (#630)<br />

This is a series of <strong>test</strong>s that are classified as audits. The switch sends messages to the BRI<br />

endpoint to perform the following <strong>test</strong>s:<br />

● Ringer Audit – This audit verifies that both the switch <strong>and</strong> the endpoint agree as to the<br />

current state of the endpoint’s ringer.<br />

● Lamps Audit – This audit verifies that both the switch <strong>and</strong> the endpoint agree as to the<br />

current state of the endpoint’s lamps.<br />

● Call Activity Audit – This audit verifies that the state of calls is consistent between the<br />

switch <strong>and</strong> the endpoint.<br />

This <strong>test</strong> is not executed for ASAI or <strong>Avaya</strong> adjunct because adjuncts do not employ ringers or<br />

lamps <strong>and</strong> do not establish calls on the B-Chels associated with the BRI interface.<br />

This <strong>test</strong> is run on BRI-SET, Various Adjuncts.<br />

Table 425: BRI Set Audits Test (#630) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1113 ABORT The signaling link between the switch <strong>and</strong> the endpoint is down.<br />

1. Enter <strong>test</strong> port location long to clear any <strong>error</strong>s that prevent<br />

establishment of the signaling link.<br />

2. Examine the results of the Signaling Link Status <strong>test</strong> (#626) that is<br />

run as part of this comm<strong>and</strong>. If this <strong>test</strong> aborts or fails, follow the<br />

repair procedure for Signaling Link Status Test (#626).<br />

3. If the BRI Set Audits <strong>test</strong> continues to abort, escalate the problem.<br />

1139 ABORT The PN’s packet bus is out-of-service.<br />

1. Follow the repair procedures for the packet bus.<br />

2. After completing step 1, enter <strong>test</strong> port location long <strong>and</strong><br />

review the results of the BRI Port Local LAN Looparound Test (#618)<br />

to verify the repair.<br />

1144 ABRT The PPN’s packet bus is out-of-service.<br />

1. Follow the repair procedures for the PPN’s packet bus.<br />

2. After completing step 1, execute <strong>test</strong> port PCSSpp long, <strong>and</strong><br />

review the results of the BRI Port Local LAN Loop Around <strong>test</strong> (#618)<br />

to verify the repair.<br />