Upgrading TN574 DS1 Converter Circuit Packs<br />

in a Fiber-Link to TN1654s — Duplicated PNC<br />

WARNING: Do<br />

WARNING: In<br />

WARNING: The<br />

WARNING: A<br />

not power down a Switch Node carrier to replace a circuit pack.<br />

DS1C-BD (DS1 Converter Circuit Pack)<br />

duplicated PNC configurations, one DS1 converter complex in the fiber-link<br />

serves as the active <strong>and</strong> the second DS1 converter complex serves as the<br />

st<strong>and</strong>by. Each DS1 Converter complex consists of two TN574 boards or two<br />

TN1654 boards. A TN574 cot be combined with a TN1654 in the same DS1<br />

converter complex. It is also required that all four DS1 converter boards <strong>and</strong><br />

interconnecting facilities that serve an PN be of the same type. Note, however,<br />

that TN574 <strong>and</strong> TN1654 boards can coexist within the same system, they just cot<br />

be in the same fiber-link.<br />

two DS1 converter boards, TN1654 <strong>and</strong> TN574, use unique “Y” cables that<br />

are incompatible with each other.<br />

TN573B (or higher-suffixed) board must be used when connecting a SNI board<br />

to a TN1654 DS1 Converter board.<br />

Table 95: Upgrading TN574 DS1 Converter Circuit Packs in a fiber-link to TN1654s —<br />

Duplicated PNC 1 of 2<br />

Steps Comments<br />

Enter status pnc. Verify that the A-PNC is active. If the B-PNC is<br />

active, enter the reset pnc interchange comm<strong>and</strong> to<br />

cause the A-PNC to go active.<br />

Enter busyout pnc-st<strong>and</strong>by. Fiber link cot be removed if PNC duplication is<br />

operational. Must busyout the st<strong>and</strong>by PNC first.<br />

Enter change system-parameters<br />

duplication. Change the Enable<br />

Operation of PNC Duplication<br />

field to n.<br />

Disable PNC duplication.<br />

Enter list fiber-link. Determine the fiber-link number that the four<br />

TN574 circuit packs to be upgraded are associated<br />

with.<br />

Enter busyout fiber-link<br />

fiber#.<br />

Enter remove fiber-link fiber#.<br />

fiber# represents the fiber-link number<br />

associated with the TN574 DS1 converter<br />

complexes that are being upgraded to TN1654<br />

DS1 converter complexes.<br />

1 of 2<br />

Issue 5 May 2009 383