3. A particular Tone-Clock circuit pack can be made active by entering set tone-clock<br />

location [override]. If the Tone-Clock to be made active is less healthy than the<br />

currently active one, no interchange will occur unless the override option is specified;<br />

without it a message will inform the user that it is required.<br />

Once a Tone-Clock circuit pack is made active by the set tone-clock location<br />

comm<strong>and</strong>, it will stay active until either the set tone-clock location comm<strong>and</strong> is<br />

entered again to make the other circuit pack active, or until a fault occurs in the active<br />

Tone-Clock circuit pack, which causes the system to interchange Tone-Clocks.<br />

S8700 series | S8500<br />

Firmware Instigated Tone-Clock Interchanges<br />

Firmware-initiated Tone-Clock interchanges occur when the auto clock switching option is<br />

enabled, <strong>and</strong> the TN2312 IPSI circuit pack firmware detects a loss of clock or clock <strong>error</strong>s. After<br />

detecting a loss of clock/clock <strong>error</strong>s, <strong>and</strong> rather than waiting for system software to request a<br />

switch, the IPSI firmware will automatically switch the clock (when auto clock switching is<br />

enabled). The auto clock switching option is disabled during system restarts.<br />

Note: The<br />

Note:<br />

auto clock switching option is required by the IPSI circuit pack since the EAL<br />

connection to the PKT-INT (one of the IPSI circuit packs many functions) is over<br />

the server packet bus which must have a good clock for proper operation.<br />

S8700-series Fiber-PNC<br />

Clock Synchronization<br />

Note:<br />

Note: Stratum-3 clocking is not available for a port network supported by a TN2312<br />

(IPSI) circuit pack, or a port network where the Tone-Clock function is supplied by<br />

a TN2182.<br />

This section discusses synchronization with a Stratum-3 or -4 clocking device.<br />

996 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers